• Address No.76 Xinda Rd.,Fenshui,Zhoutie Town,Yixing City,Jiangsu Province,China
  • Email allen@zozen.com
Menu
SZS series gas-fired (oil-fired) steam boiler

SZS series gas-fired (oil-fired) steam boiler

Processing capacity: 10-100 t/h

Working pressure: 2.5-9.8 Mpa

Get a Quote Send Message

Product introduction

SZS series boiler is designed with longitudinal double drums and " D " type chamber structure. Furnace is placed on the right and convection tube bank is on the left, super heater is arranged at convection tube bank. The body is fixed on the basement by middle and both end flexible supports and make the boiler expand horizontally sideways. Around the furnace is membrane water cooling tube wall. Furnace and tube bank are totally separated by the membrane water tube cooling wall at the left side of the furnace. The back part of bundle is sparse shift structure, front part is aligned structure. Smoke from furnace outlet enters re-burning chamber, convection tube bank area and then from left front part enters spiral fine coil economizer and condenser, and finally is discharged to atmosphere through chimney.

Product advantages

Safety
  • Boiler body uses the forced circulation in the high temperature area to make sure all heating areas can be cooled down and avoid vaporization; The explosion door and flame detector are equipped for safe and reliable operation. Comb plates are used between both sides of boiler and tube bundle to avoid leakage of condensate and gas caused by using refractory concrete as sealing material. Air proof test is done before delivery in the factory to guarantee any gas leakage problem.

Environmental protection
  • Big combustion chamber equipped with Low emission combustion burner effectively reduce the NOx to 30mg/m3. Smoke duct and smoke outlet use internal insulation to reduce operating noise.

  • Combustion chamber uses full membrane water cooling wall structure and pressurized combustion without smoke mixture. 

Energy conservation
  • Good quality alumina silicate fiber and fire clay insulation material are used and the boiler body temperature is controlled below 45℃ and greatly heat loss is  reduced. Combustion chamber is designed with narrow distance tube membrane water cooling wall which has good air proof to reduce heat lost and increase boiler thermal efficiency. Internal inspection holes uses high-alumina refractory and manhole cover seal devices, solving superheat problem in this part caused by using refractory bricks.

Convenience
  • Manholes are placed on the front and back side of drums and inspection doors on back side of boiler easy to open for inspection and clean inner and outer parts.

longer lifespan
  • Membrane structure are used in the front and back wall for boiler body and highly increased their lifespan to over 20 years.

  • The key processes including material cutting, rolling, drilling are done by advanced CNC machining process to reduce the assembly stress and extend boiler service lifetime.

  • Flutter prevention fastener is used for high temperature part convection tubes, which avoid convection tube cracking problem.

  • Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will be tested by radiographic inspection.

Show more

Technical data

Model Rated evaporation(t/h) Rated working pressure(MPa) Rated steam temperature(℃) Thermal efficiency(%)
SZS20-1.25-Q.Y 20 1.25 194 >98
SZS20-1.6-Q.Y 20 1.6 204 >98
SZS20-2.5-Q.Y 20 2.5 225 >98
SZS25-1.25-Q.Y 25 1.25 194 >98
SZS25-1.6-Q.Y 25 1.6 204 >98
SZS25-2.5-Q.Y 25 2.5 225 >98
SZS30-1.25-Q.Y 30 1.25 194 >98
SZS30-1.6-Q.Y 30 1.6 204 >98
SZS30-2.5-Q.Y 30 2.5 225 >98
SZS35-1.25-Q.Y 35 1.25 194 >98
SZS35-1.6-Q.Y 35 1.6 204 >98
SZS35-2.5-Q.Y 35 2.5 225 >98
SZS40-1.25-Q.Y 40 1.25 194 >98
SZS40-1.6-Q.Y 40 1.6 204 >98
SZS40-2.5-Q.Y 40 2.5 225 >98
SZS50-1.25-Q.Y 50 1.25 194 >98
SZS50-1.6-Q.Y 50 1.6 204 >98
SZS50-2.5-Q.Y 50 2.5 225 >98
SZS65-1.25-Q.Y 65 1.25 194 >98
SZS65-1.6-Q.Y 65 1.6 204 >98
SZS65-2.5-Q.Y 65 2.5 225 >98
SZS75-1.25-Q.Y  75 1.25 194 >98
SZS75-1.6-Q.Y 75 1.6 204 >98
SZS75-2.5-Q.Y 75 2.5 225 >98
SZS100-1.25-Q.Y  100 1.25 194 >98
SZS100-1.6-Q.Y 100 1.6 204 >98
SZS100-2.5-Q.Y 100 2.5 225 >98
Model Rated evaporation(t/h) Rated working pressure(MPa) Rated steam temperature(℃) Thermal efficiency(%)
SZS20-1.25-Q.Y 20 1.25 194 >98
SZS20-1.6-Q.Y 20 1.6 204 >98
SZS20-2.5-Q.Y 20 2.5 225 >98
SZS25-1.25-Q.Y 25 1.25 194 >98
SZS25-1.6-Q.Y 25 1.6 204 >98
SZS25-2.5-Q.Y 25 2.5 225 >98
SZS30-1.25-Q.Y 30 1.25 194 >98
SZS30-1.6-Q.Y 30 1.6 204 >98
SZS30-2.5-Q.Y 30 2.5 225 >98
SZS35-1.25-Q.Y 35 1.25 194 >98
SZS35-1.6-Q.Y 35 1.6 204 >98
SZS35-2.5-Q.Y 35 2.5 225 >98
SZS40-1.25-Q.Y 40 1.25 194 >98
SZS40-1.6-Q.Y 40 1.6 204 >98
SZS40-2.5-Q.Y 40 2.5 225 >98
SZS50-1.25-Q.Y 50 1.25 194 >98
SZS50-1.6-Q.Y 50 1.6 204 >98
SZS50-2.5-Q.Y 50 2.5 225 >98
SZS65-1.25-Q.Y 65 1.25 194 >98
SZS65-1.6-Q.Y 65 1.6 204 >98
SZS65-2.5-Q.Y 65 2.5 225 >98
SZS75-1.25-Q.Y  75 1.25 194 >98
SZS75-1.6-Q.Y 75 1.6 204 >98
SZS75-2.5-Q.Y 75 2.5 225 >98
SZS100-1.25-Q.Y  100 1.25 194 >98
SZS100-1.6-Q.Y 100 1.6 204 >98
SZS100-2.5-Q.Y 100 2.5 225 >98

HOT PRODUCT

YLW series coal-fired/biomass-fired thermal fluid heater

YLW series coal-fired/biomass-fired thermal fluid heater

Processing capacity: 1400-29000 KW
Working pressure: 0.8-1.0 MPA

WNS series gas-fired (oil-fired) steam boiler

WNS series gas-fired (oil-fired) steam boiler

Processing capacity: 1-20 t/h
Working pressure: 0.7-2 Mpa

SZS series gas-fired (oil-fired) hot water boiler

SZS series gas-fired (oil-fired) hot water boiler

Processing capacity: 7-116 MW
Working pressure: 1.0-1.6 Mpa

WNS series gas-fired (oil-fired) hot water boiler

WNS series gas-fired (oil-fired) hot water boiler

Processing capacity: 0.7-14 MW
Working pressure: 0.7-1.25 Mpa

SZS series gas-fired (oil-fired) steam boiler

SZS series gas-fired (oil-fired) steam boiler

Processing capacity: 10-100 t/h
Working pressure: 2.5-9.8 Mpa

DZL series coal-fired steam boiler

DZL series coal-fired steam boiler

Processing capacity: 2 – 20t/h
Working pressure: 1.0-2.5 MPA

DHL series coal-fired steam boiler

DHL series coal-fired steam boiler

Processing capacity: 20-75 t/h
Working pressure: 1.25-5.4 MPA

SHX coal-fired CFB (circulating fluidized bed) steam boiler

SHX coal-fired CFB (circulating fluidized bed) steam boiler

Processing capacity: 10 - 75 t/h
Working pressure: 1.25-2.45MPA

DHX coal-fired CFB (circulating fluidized bed) steam boiler

DHX coal-fired CFB (circulating fluidized bed) steam boiler

Processing capacity: 35-75 t/h
Working pressure: 1.25-5.3 MPA

SZL series coal-fired steam boiler

SZL series coal-fired steam boiler

Processing capacity: 4-35 t/h
Working pressure: 1.0-2.5 MPA

Need help? welcome to contact us

Our company can provide the whole spare parts of boiler equipment produced by us, with excellent features such as reliable performance characteristics, durable usage, all kinds of types in order to satisfy the requirement of customers in time and to reduce the maintenance time at the same time. Welcome to browse our website and leave us a message

Email allen@zozen.com

We will strictly protect the privacy of users'personal information and never disclose it.

Quick Way To Get Price

Need More Information About Our Products and Price?
Simply Contact Us, We Are Waiting for You!